----- Original Message ----- 
  
  
  Sent: Friday, June 20, 2003 10:01 
AM
  Subject: [oc] vhdl question
  
  Hey guys,
  I had a question. I have a combinational 
  statement in VHDL as given below.
   
  start <= '1' when read='1' and addr(7 downto 
  0)="11111111" else '0';
   
  Now what happens here is that read goes high only 
  for one clock cycle and hence so does start. How can I make start stay high 
  for 2 or more clock cycles and then go low ? 
   
  -----------------------------------------------------------------
Saumil 
  Merchant
University of Tennessee
http://web.utk.edu/~smerchan
-----------------------------------------------------------------