SNMP Traps

Receiver Side
To Set a Client Listening to SNMP Traps:
Step 1: Right-click on the lower half of the configuration screen, the receiver entry field, to display the add recipient prompt.

Step 2: An Add receiver prompt displays. Simply enter the IP addresses of SNMP agents for trap notification.

Step 3: Select the severity level of events to be sent to the SNMP agent.
Step 4: Repeat this process to add more SNMP agents.


Sender Side
From the Module Config window:
Step 1: Find the SNMP settings from the pull-down list
Step 2: Click on the On/Off switch besides the pull-down button to enable SNMP Traps notification.
switched ON switched OFF
Step 3: Set Status to Enable if you want the module to be activated every time the Configuration Client is started. Note that the On/Off switch should also be in the On position before you turned off the server or closed the utility. Otherwise, you will have to manually enable the function.
Step 4: Select the severity level of events to be sent to the receiver station.
Step 5: Provide a valid out port IP that will be used for delivering SNMP traps. Usually the default IP detected by the Root Agent will be sufficient. If you have more than one Ethernet port, double-click to configure it.


Back to Configuration Client page