SNMP Traps
Receiver Side
To Set a Client Listening to SNMP Traps:
Step 1: Right-click on the lower half of the configuration screen, the receiver
entry field, to display the add recipient prompt.
Step 2: An Add receiver prompt displays. Simply enter the IP
addresses of SNMP agents for trap notification.
Step 3: Select the severity level of events to be sent to the
SNMP agent.
Step 4: Repeat this process to add more SNMP agents.
Sender Side
From the Module Config window:
Step 1: Find the SNMP settings from the pull-down list
Step 2: Click on the On/Off switch besides the pull-down button to enable SNMP
Traps notification.
switched ON
switched OFF
Step 3: Set Status to Enable if you want the module to be activated
every time the Configuration Client is started. Note that the On/Off switch
should also be in the ON position before you turned off the server or closed
the utility. Otherwise, you will have to manually enable the function.
Step 4: Select the
severity level of events to be sent to the receiver station.
Step 5: Provide a valid out port IP that will be used for delivering
SNMP traps. Usually the default IP detected by the Root Agent will be sufficient.
If you have more than one Ethernet port, double-click to configure it.
Back to Configuration Client page